What E17 actually means

The fridge freezer has spotted a problem with the flap fan — one of the small internal fans that moves cold air around inside \— and it has flagged it rather than carrying on quietly.

Blomberg's control board watches each fan and expects to see it turning at the right speed whenever it is called for. On this code the fan associated with the air-flap (the motorised vent that shares cold air between compartments) either isn't running or isn't reporting back properly, so the board raises the fault on the display. Cooling elsewhere usually continues, but air distribution to one compartment can suffer, so temperatures may start to drift.

What E17 looks like on a Blomberg fridge freezer

Most people find this page having searched for what the machine is doing rather than the code itself. On a Blomberg fridge freezer, E17 usually shows up as one or more of these:

  • Fridge freezer not draining
  • Water left in the machine at the end of the cycle
  • Stops mid-cycle full of water
  • Standing water in the bottom
  • Machine not turning
  • Won't spin
  • Hums or buzzes but nothing moves
  • Turns one way only

Recognise any of those? That is this fault, and the rest of this page explains what causes it and what you can check yourself.

What usually causes it

  • The flap fan motor has failed or seized
  • Ice built up around the fan blade stopping it turning
  • A loose or damaged connection to the fan
  • Food or packaging pushed against the internal air vents
  • A control board fault misreading the fan's feedback signal

What you can safely check yourself

Work through these in order. Anything beyond this — panels off, testing parts, anything to do with the wiring — is an engineer's job, and not one to attempt with the machine plugged in.

  1. Turn the appliance off at the socket for a minute, then switch it back on \— the code sometimes clears if the fault was momentary
  2. Check nothing is packed tight against the vents inside, particularly bags or boxes near the top of the compartments
  3. Make sure both doors are closing and sealing properly \— warm air getting in is what causes the ice build-up that jams these fans
  4. If you can see frost or ice around an internal air vent, empty the appliance and let it defrost fully, then restart it
  5. Keep an eye on fridge and freezer temperatures until an engineer attends, and move anything that must not thaw

Which Blomberg models show E17

E17 means the same thing on this model. If yours is not listed, the explanation above still applies — the code is set by the control board, not the model number.

7287745715

Common questions about Blomberg E17

What does E17 mean on a Blomberg fridge freezer?

The fridge freezer has spotted a problem with the flap fan — one of the small internal fans that moves cold air around inside \— and it has flagged it rather than carrying on quietly. Blomberg's control board watches each fan and expects to see it turning at the right speed whenever it is called for. On this code the fan associated with the air-flap (the motorised vent that shares cold air between compartments) either isn't running or isn't reporting back properly, so the board raises the fault on the display. Cooling elsewhere usually continues, but air distribution to one compartment can suffer, so temperatures may start to drift.

Can I fix Blomberg E17 myself?

There are 5 checks you can safely do yourself first.

  1. Turn the appliance off at the socket for a minute, then switch it back on \— the code sometimes clears if the fault was momentary.
  2. Check nothing is packed tight against the vents inside, particularly bags or boxes near the top of the compartments.
  3. Make sure both doors are closing and sealing properly \— warm air getting in is what causes the ice build-up that jams these fans.
  4. If you can see frost or ice around an internal air vent, empty the appliance and let it defrost fully, then restart it.
  5. Keep an eye on fridge and freezer temperatures until an engineer attends, and move anything that must not thaw.

This one usually needs an engineer once you have tried them.

How much does it cost to repair Blomberg E17?

£66 including VAT for an engineer to come out and diagnose it, or £84 in total including VAT if it is put right on the visit and no parts are needed. Any parts needed are quoted on site before we fit them — you decide. Every repair carries a 90-day workmanship guarantee.

Tried the checks and it's still showing E17?

This one usually needs an engineer once you have tried the checks above. Then it wants someone who can open it up.

What it costs, before you call: the price is the same whatever the fault turns out to be — £66 including VAT for an engineer to come out and diagnose it, or £84 in total including VAT if it is put right on the visit and no parts are needed. Any parts needed are quoted on site before we fit them — you decide. Every repair carries a 90-day workmanship guarantee.

Our own engineers, not a call centre. We cover Nottinghamshire, Derbyshire and Leicestershire — most fridge freezer faults are seen same day or next day.

Call 0115 648 0929 Book online — postcode and number is all we need

Outside our area? The explanation above still stands — take it to a local engineer and tell them the code. Knowing it saves them time and you money.

Other Blomberg fridge freezer codes

What this looks like when it happens

Repairs we cover near you

Need it looked at properly?

Call us today for fast, reliable appliance repairs from local experts.

0115 648 0929
Call 0115 648 0929