What E10 actually means
The temperature sensor for the convertible "joker" compartment — the one that can be set to run as either a fridge or a freezer — has failed electrically, so the control board no longer knows how cold that compartment is.
Blomberg's frost-free fridge freezers with a switchable compartment use an air sensor in that compartment to decide when to call for cooling and when to open the flap that feeds cold air into it. E10 is logged when the board sees that sensor as an open circuit or a short circuit, and the alarm indicator lights up with the code. Rather than stop cooling altogether, the appliance drops into a fixed timed pattern of running and resting, which is why the compartment often still feels cold but drifts warmer or colder than the setting you've chosen.
What E10 looks like on a Blomberg fridge freezer
Most people find this page having searched for what the machine is doing rather than the code itself. On a Blomberg fridge freezer, E10 usually shows up as one or more of these:
- Fridge freezer door won't open
- Door won't lock or click shut
- Door lock light flashing
- Door stuck shut with the load inside
- Won't start even with the door closed
- Not heating the water
- Washing coming out cold
- Cycle takes far longer than it should
Recognise any of those? That is this fault, and the rest of this page explains what causes it and what you can check yourself.
What usually causes it
- Faulty air sensor (thermistor) in the convertible compartment
- A damaged or chafed sensor lead, often where the wiring passes into the cabinet
- Corroded or loose sensor connector, usually from moisture or a previous defrost problem
- Control board fault misreading a sensor that is actually sound — less common, and worth ruling the sensor out first
What you can safely check yourself
Work through these in order. Anything beyond this — panels off, testing parts, anything to do with the wiring — is an engineer's job, and not one to attempt with the machine plugged in.
- Switch the appliance off at the socket for a minute, then back on — if the sensor connection was only briefly disturbed, a stored fault can clear on power-up
- Check nothing inside the compartment is jammed against the back or side walls where the sensor and air vents sit
- Make sure the door is closing fully and the seal is not folded over, so warm damp air isn't being drawn in and icing things up
- Note whether the compartment is actually holding temperature, and move anything perishable to a compartment that is — that tells the engineer a lot
Which Blomberg models show E10
E10 means the same thing on all 3 of these models. If yours is not listed, the explanation above still applies — the code is set by the control board, not the model number.
7263646283 · 7264346383 · 7287745715
Common questions about Blomberg E10
What does E10 mean on a Blomberg fridge freezer?
The temperature sensor for the convertible "joker" compartment — the one that can be set to run as either a fridge or a freezer — has failed electrically, so the control board no longer knows how cold that compartment is. Blomberg's frost-free fridge freezers with a switchable compartment use an air sensor in that compartment to decide when to call for cooling and when to open the flap that feeds cold air into it. E10 is logged when the board sees that sensor as an open circuit or a short circuit, and the alarm indicator lights up with the code. Rather than stop cooling altogether, the appliance drops into a fixed timed pattern of running and resting, which is why the compartment often still feels cold but drifts warmer or colder than the setting you've chosen.
Can I fix Blomberg E10 myself?
There are 4 checks you can safely do yourself first.
- Switch the appliance off at the socket for a minute, then back on — if the sensor connection was only briefly disturbed, a stored fault can clear on power-up.
- Check nothing inside the compartment is jammed against the back or side walls where the sensor and air vents sit.
- Make sure the door is closing fully and the seal is not folded over, so warm damp air isn't being drawn in and icing things up.
- Note whether the compartment is actually holding temperature, and move anything perishable to a compartment that is — that tells the engineer a lot.
This one usually needs an engineer once you have tried them.
How much does it cost to repair Blomberg E10?
£66 including VAT for an engineer to come out and diagnose it, or £84 in total including VAT if it is put right on the visit and no parts are needed. Any parts needed are quoted on site before we fit them — you decide. Every repair carries a 90-day workmanship guarantee.
Tried the checks and it's still showing E10?
This one usually needs an engineer once you have tried the checks above. Then it wants someone who can open it up.
What it costs, before you call: the price is the same whatever the fault turns out to be — £66 including VAT for an engineer to come out and diagnose it, or £84 in total including VAT if it is put right on the visit and no parts are needed. Any parts needed are quoted on site before we fit them — you decide. Every repair carries a 90-day workmanship guarantee.
Our own engineers, not a call centre. We cover Nottinghamshire, Derbyshire and Leicestershire — most fridge freezer faults are seen same day or next day.
Call 0115 648 0929 Book online — postcode and number is all we need
Outside our area? The explanation above still stands — take it to a local engineer and tell them the code. Knowing it saves them time and you money.
Other Blomberg fridge freezer codes
- Blomberg E11 — The temperature sensor on the evaporator (the cooling coil) …
- Blomberg E12 — The heater that melts frost off the cooling plate in the con…
- Blomberg E13 — The control board has decided the motorised flap that lets c…
- Blomberg E14 — One of the fridge freezer's internal cooling fans has stoppe…
- Blomberg E15 — The control board has lost the expected signal from the cond…
- Blomberg E16 — The fan that circulates cold air around the fridge section i…
- Blomberg E17 — The fridge freezer has spotted a problem with the flap fan …
- Blomberg E18 — The fan that circulates cold air through the BioFresh compar…
All Blomberg fault codes and repairs →