What E12 actually means
The heater that melts frost off the cooling plate in the convertible freezer/larder compartment isn't reading correctly, so the fridge freezer has flagged it and stopped defrosting that section.
Blomberg's control board watches the defrost heater circuit in the switchable "freezer/larder" compartment. If it sees an open circuit or a short there, it puts up E12 along with the alarm indicator and gives up on running that defrost. The compartment usually keeps getting cold for a while, but frost slowly builds on the evaporator behind the back wall, airflow chokes off and temperatures start drifting up — that creeping loss of cooling is normally what brings people to look at the display in the first place.
What E12 looks like on a Blomberg fridge freezer
Most people find this page having searched for what the machine is doing rather than the code itself. On a Blomberg fridge freezer, E12 usually shows up as one or more of these:
- Fridge freezer not draining
- Water left in the machine at the end of the cycle
- Stops mid-cycle full of water
- Standing water in the bottom
- Not heating the water
- Washing coming out cold
- Cycle takes far longer than it should
- Not cooling
Recognise any of those? That is this fault, and the rest of this page explains what causes it and what you can check yourself.
What usually causes it
- Failed defrost heater element in the freezer/larder compartment
- A broken or corroded connection at the heater, which the board reads as an open circuit
- Damaged wiring or a chafed lead in the defrost circuit
- Thermal cut-out in the defrost circuit gone open
- Control board misreading the heater circuit
What you can safely check yourself
Work through these in order. Anything beyond this — panels off, testing parts, anything to do with the wiring — is an engineer's job, and not one to attempt with the machine plugged in.
- Switch the appliance off at the socket for a minute and back on — if the fault has genuinely cleared, the code drops out on restart, and if it comes straight back you know it's a real fault.
- Check the doors are closing fully and the seals aren't folded over or sticky, since warm moist air pulled in makes frosting far worse.
- Make sure food and packaging aren't pressed against the back wall or blocking the vents inside that compartment.
- If there's already heavy frost, empty the compartment and let it defrost fully with the appliance off — this won't fix E12, but it tells you how far things have gone.
Which Blomberg models show E12
E12 means the same thing on all 2 of these models. If yours is not listed, the explanation above still applies — the code is set by the control board, not the model number.
7264346383 · 7287745715
Common questions about Blomberg E12
What does E12 mean on a Blomberg fridge freezer?
The heater that melts frost off the cooling plate in the convertible freezer/larder compartment isn't reading correctly, so the fridge freezer has flagged it and stopped defrosting that section. Blomberg's control board watches the defrost heater circuit in the switchable "freezer/larder" compartment. If it sees an open circuit or a short there, it puts up E12 along with the alarm indicator and gives up on running that defrost. The compartment usually keeps getting cold for a while, but frost slowly builds on the evaporator behind the back wall, airflow chokes off and temperatures start drifting up — that creeping loss of cooling is normally what brings people to look at the display in the first place.
Can I fix Blomberg E12 myself?
There are 4 checks you can safely do yourself first.
- Switch the appliance off at the socket for a minute and back on — if the fault has genuinely cleared, the code drops out on restart, and if it comes straight back you know it's a real fault.
- Check the doors are closing fully and the seals aren't folded over or sticky, since warm moist air pulled in makes frosting far worse.
- Make sure food and packaging aren't pressed against the back wall or blocking the vents inside that compartment.
- If there's already heavy frost, empty the compartment and let it defrost fully with the appliance off — this won't fix E12, but it tells you how far things have gone.
This one usually needs an engineer once you have tried them.
How much does it cost to repair Blomberg E12?
£66 including VAT for an engineer to come out and diagnose it, or £84 in total including VAT if it is put right on the visit and no parts are needed. Any parts needed are quoted on site before we fit them — you decide. Every repair carries a 90-day workmanship guarantee.
Tried the checks and it's still showing E12?
This one usually needs an engineer once you have tried the checks above. Then it wants someone who can open it up.
What it costs, before you call: the price is the same whatever the fault turns out to be — £66 including VAT for an engineer to come out and diagnose it, or £84 in total including VAT if it is put right on the visit and no parts are needed. Any parts needed are quoted on site before we fit them — you decide. Every repair carries a 90-day workmanship guarantee.
Our own engineers, not a call centre. We cover Nottinghamshire, Derbyshire and Leicestershire — most fridge freezer faults are seen same day or next day.
Call 0115 648 0929 Book online — postcode and number is all we need
Outside our area? The explanation above still stands — take it to a local engineer and tell them the code. Knowing it saves them time and you money.
Other Blomberg fridge freezer codes
- Blomberg E13 — The control board has decided the motorised flap that lets c…
- Blomberg E14 — One of the fridge freezer's internal cooling fans has stoppe…
- Blomberg E15 — The control board has lost the expected signal from the cond…
- Blomberg E16 — The fan that circulates cold air around the fridge section i…
- Blomberg E17 — The fridge freezer has spotted a problem with the flap fan …
- Blomberg E18 — The fan that circulates cold air through the BioFresh compar…
- Blomberg E19 — The fridge has lost a proper reading from the temperature se…
- Blomberg E20 — The temperature sensor that watches the BioFRESH compartment…
All Blomberg fault codes and repairs →