What E13 actually means
The control board has decided the motorised flap that lets cold air into the fridge section isn't working properly, so it has flagged a fault.
On these no-frost Blomberg fridge freezers, cold air is made in one place and shared out; a small motorised flap (damper) opens and closes to feed the fridge compartment. The control watches for that flap cycling open and shut, and if it sees no change of state for around 400 minutes it logs E13. Cooling normally continues in some form, but the fridge side often drifts warm or over-chills because the airflow is no longer being controlled.
What E13 looks like on a Blomberg fridge freezer
Most people find this page having searched for what the machine is doing rather than the code itself. On a Blomberg fridge freezer, E13 usually shows up as one or more of these:
- Fridge freezer not draining
- Water left in the machine at the end of the cycle
- Stops mid-cycle full of water
- Standing water in the bottom
- Overfilling, or won't stop filling
- Stops with water still inside
- Fills and drains over and over
- Machine not turning
Recognise any of those? That is this fault, and the rest of this page explains what causes it and what you can check yourself.
What usually causes it
- The flap motor or damper mechanism has failed or is stuck
- Ice build-up around the flap jamming it in one position
- A wiring or connector fault between the flap and the control board
- Food packaging or an overfilled shelf pressing against the air outlet
- A control board that has lost the feedback signal from the flap
What you can safely check yourself
Work through these in order. Anything beyond this — panels off, testing parts, anything to do with the wiring — is an engineer's job, and not one to attempt with the machine plugged in.
- Make sure nothing is packed hard against the air vents or the flap opening at the back of the fridge compartment — leave a clear gap
- Check the doors are closing and sealing properly, and that a drawer or bottle isn't holding one slightly ajar, as warm damp air causes icing around the flap
- Switch off at the wall for a minute and back on; if the fault has genuinely cleared, the code will not return
- If you can see frost or ice around the fridge air outlet, empty the appliance and let it stand switched off with the doors open until it has fully thawed, then restart it
Which Blomberg models show E13
E13 means the same thing on all 2 of these models. If yours is not listed, the explanation above still applies — the code is set by the control board, not the model number.
7263646283 · 7287745715
Common questions about Blomberg E13
What does E13 mean on a Blomberg fridge freezer?
The control board has decided the motorised flap that lets cold air into the fridge section isn't working properly, so it has flagged a fault. On these no-frost Blomberg fridge freezers, cold air is made in one place and shared out; a small motorised flap (damper) opens and closes to feed the fridge compartment. The control watches for that flap cycling open and shut, and if it sees no change of state for around 400 minutes it logs E13. Cooling normally continues in some form, but the fridge side often drifts warm or over-chills because the airflow is no longer being controlled.
Can I fix Blomberg E13 myself?
There are 4 checks you can safely do yourself first.
- Make sure nothing is packed hard against the air vents or the flap opening at the back of the fridge compartment — leave a clear gap.
- Check the doors are closing and sealing properly, and that a drawer or bottle isn't holding one slightly ajar, as warm damp air causes icing around the flap.
- Switch off at the wall for a minute and back on; if the fault has genuinely cleared, the code will not return.
- If you can see frost or ice around the fridge air outlet, empty the appliance and let it stand switched off with the doors open until it has fully thawed, then restart it.
This one usually needs an engineer once you have tried them.
How much does it cost to repair Blomberg E13?
£66 including VAT for an engineer to come out and diagnose it, or £84 in total including VAT if it is put right on the visit and no parts are needed. Any parts needed are quoted on site before we fit them — you decide. Every repair carries a 90-day workmanship guarantee.
Tried the checks and it's still showing E13?
This one usually needs an engineer once you have tried the checks above. Then it wants someone who can open it up.
What it costs, before you call: the price is the same whatever the fault turns out to be — £66 including VAT for an engineer to come out and diagnose it, or £84 in total including VAT if it is put right on the visit and no parts are needed. Any parts needed are quoted on site before we fit them — you decide. Every repair carries a 90-day workmanship guarantee.
Our own engineers, not a call centre. We cover Nottinghamshire, Derbyshire and Leicestershire — most fridge freezer faults are seen same day or next day.
Call 0115 648 0929 Book online — postcode and number is all we need
Outside our area? The explanation above still stands — take it to a local engineer and tell them the code. Knowing it saves them time and you money.
Other Blomberg fridge freezer codes
- Blomberg E14 — One of the fridge freezer's internal cooling fans has stoppe…
- Blomberg E15 — The control board has lost the expected signal from the cond…
- Blomberg E16 — The fan that circulates cold air around the fridge section i…
- Blomberg E17 — The fridge freezer has spotted a problem with the flap fan …
- Blomberg E18 — The fan that circulates cold air through the BioFresh compar…
- Blomberg E19 — The fridge has lost a proper reading from the temperature se…
- Blomberg E20 — The temperature sensor that watches the BioFRESH compartment…
- Blomberg E21 — The fridge section got too warm for too long, and the applia…
All Blomberg fault codes and repairs →