What E13 actually means
The fan that circulates cold air around the freezer section isn't turning as it should, and the appliance has flagged it.
Each of these fridge freezers uses a fan inside the freezer compartment to push cold air off the evaporator and around the food, and on the wiring used here the fan reports back to the control board. When that feedback stops or the fan stalls, E13 appears. The compressor generally keeps running, but without air movement the cold stays trapped at the evaporator — so the freezer warms up unevenly and frost builds up where the air should be flowing.
What E13 looks like on a Flavel fridge freezer
Most people find this page having searched for what the machine is doing rather than the code itself. On a Flavel fridge freezer, E13 usually shows up as one or more of these:
- Fridge freezer door won't open
- Door won't lock or click shut
- Door lock light flashing
- Door stuck shut with the load inside
- Won't start even with the door closed
- Fridge freezer not draining
- Water left in the machine at the end of the cycle
- Stops mid-cycle full of water
Recognise any of those? That is this fault, and the rest of this page explains what causes it and what you can check yourself.
What usually causes it
- Ice or frost build-up jamming the fan blade
- Food packaging or an over-filled drawer pressed against the fan housing
- Failed freezer fan motor
- Loose or displaced plug on the fan's feedback wiring at the control board
- Control board not reading the fan's feedback signal
What you can safely check yourself
Work through these in order. Anything beyond this — panels off, testing parts, anything to do with the wiring — is an engineer's job, and not one to attempt with the machine plugged in.
- Take out anything packed tightly against the back wall or top of the freezer, where the air outlets are, and leave a gap for air to move.
- Switch off at the wall for a minute, then back on, and see whether the code returns.
- If there is heavy frost inside, empty the freezer and let it defrost fully with the door open — a blade frozen solid sometimes frees itself and the code clears.
- Check the freezer door is closing and sealing properly; warm damp air getting in is what causes the frost that jams the fan.
- While the fault is present, keep door openings short and don't put warm food in — the advice, and it limits how far the temperature drifts.
Which Flavel models show E13
E13 means the same thing on all 2 of these models. If yours is not listed, the explanation above still applies — the code is set by the control board, not the model number.
7248541919 · 7248741919
Common questions about Flavel E13
What does E13 mean on a Flavel fridge freezer?
The fan that circulates cold air around the freezer section isn't turning as it should, and the appliance has flagged it. Each of these fridge freezers uses a fan inside the freezer compartment to push cold air off the evaporator and around the food, and on the wiring used here the fan reports back to the control board. When that feedback stops or the fan stalls, E13 appears. The compressor generally keeps running, but without air movement the cold stays trapped at the evaporator — so the freezer warms up unevenly and frost builds up where the air should be flowing.
Can I fix Flavel E13 myself?
There are 5 checks you can safely do yourself first.
- Take out anything packed tightly against the back wall or top of the freezer, where the air outlets are, and leave a gap for air to move.
- Switch off at the wall for a minute, then back on, and see whether the code returns.
- If there is heavy frost inside, empty the freezer and let it defrost fully with the door open — a blade frozen solid sometimes frees itself and the code clears.
- Check the freezer door is closing and sealing properly; warm damp air getting in is what causes the frost that jams the fan.
- While the fault is present, keep door openings short and don't put warm food in — the advice, and it limits how far the temperature drifts.
This one usually needs an engineer once you have tried them.
How much does it cost to repair Flavel E13?
£66 including VAT for an engineer to come out and diagnose it, or £84 in total including VAT if it is put right on the visit and no parts are needed. Any parts needed are quoted on site before we fit them — you decide. Every repair carries a 90-day workmanship guarantee.
Tried the checks and it's still showing E13?
This one usually needs an engineer once you have tried the checks above. Then it wants someone who can open it up.
What it costs, before you call: the price is the same whatever the fault turns out to be — £66 including VAT for an engineer to come out and diagnose it, or £84 in total including VAT if it is put right on the visit and no parts are needed. Any parts needed are quoted on site before we fit them — you decide. Every repair carries a 90-day workmanship guarantee.
Our own engineers, not a call centre. We cover Nottinghamshire, Derbyshire and Leicestershire — most fridge freezer faults are seen same day or next day.
Call 0115 648 0929 Book online — postcode and number is all we need
Outside our area? The explanation above still stands — take it to a local engineer and tell them the code. Knowing it saves them time and you money.
Other Flavel fridge freezer codes
- Flavel E14 — The fan that circulates cold air through the convertible "Mu…
- Flavel E15 — The fan that cools the condenser coil at the back of the app…
- Flavel E16 — The fan that circulates cold air around the fridge (fresh fo…
- Flavel E17 — The control board has lost the feedback signal from the flap…
- Flavel E18 — The fan that circulates cold air through the Biofresh (crisp…
- Flavel E19 — The temperature sensor that reads the air at the flap (the f…
- Flavel E20 — The temperature sensor for the Biofresh (crisper/fresh-stora…
- Flavel E22 — The fridge freezer's network (Wi-Fi) card has failed a conne…
All Flavel fault codes and repairs →