What E20 actually means
The temperature sensor for the Biofresh (crisper/fresh-storage) drawer has stopped giving the control board a sensible reading.
Each compartment has its own air sensor telling the control board how cold it is in there. On E20 the board has lost a believable signal from the Biofresh compartment's air sensor — either an open circuit, a short, or a resistance well outside the expected range — so it flags the fault and falls back on a default cooling pattern for that drawer. The fridge and freezer sections normally carry on running, but the Biofresh drawer is no longer being held at its proper temperature.
What E20 looks like on a Flavel fridge freezer
Most people find this page having searched for what the machine is doing rather than the code itself. On a Flavel fridge freezer, E20 usually shows up as one or more of these:
- Overfilling, or won't stop filling
- Stops with water still inside
- Fills and drains over and over
- Not heating the water
- Washing coming out cold
- Cycle takes far longer than it should
- Not cooling
- Freezer not freezing
Recognise any of those? That is this fault, and the rest of this page explains what causes it and what you can check yourself.
What usually causes it
- The Biofresh air sensor itself has failed — much the commonest finding
- A loose or partly unseated plug where the sensor wiring meets the control board
- Chafed or broken sensor wiring, often where it passes into the cabinet
- Moisture or ice around the sensor giving false readings
- A fault on the control board reading the sensor (less common)
What you can safely check yourself
Work through these in order. Anything beyond this — panels off, testing parts, anything to do with the wiring — is an engineer's job, and not one to attempt with the machine plugged in.
- Turn the appliance off at the socket for a minute, then switch back on — if the reading glitched rather than failed, the code clears and stays clear
- Note whether the code returns straight away or after a few hours; that is genuinely useful information for the engineer
- Check the Biofresh drawer isn't overfilled or packed hard against the back wall, blocking airflow over the sensor
- Move anything delicate — salad, fish, meat — out of the Biofresh drawer into the main fridge until it's fixed
Which Flavel models show E20
E20 means the same thing on all 2 of these models. If yours is not listed, the explanation above still applies — the code is set by the control board, not the model number.
7248541919 · 7248741919
Common questions about Flavel E20
What does E20 mean on a Flavel fridge freezer?
The temperature sensor for the Biofresh (crisper/fresh-storage) drawer has stopped giving the control board a sensible reading. Each compartment has its own air sensor telling the control board how cold it is in there. On E20 the board has lost a believable signal from the Biofresh compartment's air sensor — either an open circuit, a short, or a resistance well outside the expected range — so it flags the fault and falls back on a default cooling pattern for that drawer. The fridge and freezer sections normally carry on running, but the Biofresh drawer is no longer being held at its proper temperature.
Can I fix Flavel E20 myself?
There are 4 checks you can safely do yourself first.
- Turn the appliance off at the socket for a minute, then switch back on — if the reading glitched rather than failed, the code clears and stays clear.
- Note whether the code returns straight away or after a few hours; that is genuinely useful information for the engineer.
- Check the Biofresh drawer isn't overfilled or packed hard against the back wall, blocking airflow over the sensor.
- Move anything delicate — salad, fish, meat — out of the Biofresh drawer into the main fridge until it's fixed.
This one usually needs an engineer once you have tried them.
How much does it cost to repair Flavel E20?
£66 including VAT for an engineer to come out and diagnose it, or £84 in total including VAT if it is put right on the visit and no parts are needed. Any parts needed are quoted on site before we fit them — you decide. Every repair carries a 90-day workmanship guarantee.
Tried the checks and it's still showing E20?
This one usually needs an engineer once you have tried the checks above. Then it wants someone who can open it up.
What it costs, before you call: the price is the same whatever the fault turns out to be — £66 including VAT for an engineer to come out and diagnose it, or £84 in total including VAT if it is put right on the visit and no parts are needed. Any parts needed are quoted on site before we fit them — you decide. Every repair carries a 90-day workmanship guarantee.
Our own engineers, not a call centre. We cover Nottinghamshire, Derbyshire and Leicestershire — most fridge freezer faults are seen same day or next day.
Call 0115 648 0929 Book online — postcode and number is all we need
Outside our area? The explanation above still stands — take it to a local engineer and tell them the code. Knowing it saves them time and you money.
Other Flavel fridge freezer codes
- Flavel E22 — The fridge freezer's network (Wi-Fi) card has failed a conne…
- Flavel E23 — The fridge freezer's network connection has failed a self-ch…
- Flavel E24 — The fan that moves cold air around the fridge (fresh food) s…
- Flavel E25 — The control board has lost a sensible reading from the tempe…
- Flavel E26 — The fridge has spotted that one of its UVC lamps — the ultra…
- Flavel E31 — The main control board has lost communication with the Cool …
- Flavel E42 — The temperature sensor for the soft-freeze compartment has s…
- Flavel E54 — The ice maker hasn't got cold enough to release ice, and aft…
All Flavel fault codes and repairs →