What E08 actually means
The temperature sensor inside the automatic ice maker has stopped giving a sensible reading, so the control board has shut the ice-making side down.
This code points at the ice maker's own air sensor — a small thermistor that tells the board how cold the ice compartment is so it knows when to release cubes and refill the mould. The board has seen that sensor reading as either open circuit or short circuit, which it treats as a fault and flags with the alarm indicator. Cooling in the fridge and freezer compartments is controlled by separate sensors, so the food side normally carries on working; what you lose is reliable automatic ice.
What E08 looks like on a Blomberg fridge freezer
Most people find this page having searched for what the machine is doing rather than the code itself. On a Blomberg fridge freezer, E08 usually shows up as one or more of these:
- Not filling with water
- No water going in
- Takes for ever to fill
- Stops right at the start of the cycle
- Not heating the water
- Washing coming out cold
- Cycle takes far longer than it should
- Not cooling
Recognise any of those? That is this fault, and the rest of this page explains what causes it and what you can check yourself.
What usually causes it
- A faulty ice maker air sensor (thermistor)
- A loose, damaged or corroded plug on the sensor wiring behind the ice maker
- Water or ice ingress around the sensor causing a short
- A control board that has stopped reading the sensor circuit correctly
What you can safely check yourself
Work through these in order. Anything beyond this — panels off, testing parts, anything to do with the wiring — is an engineer's job, and not one to attempt with the machine plugged in.
- Switch the appliance off at the socket for a minute, then back on — occasionally the alarm was a one-off reading and clears
- If the ice maker is switched off in the menu, turn it back on and see whether the code returns
- Check the ice bin and dispenser chute are not blocked with a solid lump of ice, and clear anything obvious by hand
Which Blomberg models show E08
E08 means the same thing on all 3 of these models. If yours is not listed, the explanation above still applies — the code is set by the control board, not the model number.
7219945781 · 7264346383 · 7287745715
Common questions about Blomberg E08
What does E08 mean on a Blomberg fridge freezer?
The temperature sensor inside the automatic ice maker has stopped giving a sensible reading, so the control board has shut the ice-making side down. This code points at the ice maker's own air sensor — a small thermistor that tells the board how cold the ice compartment is so it knows when to release cubes and refill the mould. The board has seen that sensor reading as either open circuit or short circuit, which it treats as a fault and flags with the alarm indicator. Cooling in the fridge and freezer compartments is controlled by separate sensors, so the food side normally carries on working; what you lose is reliable automatic ice.
Can I fix Blomberg E08 myself?
There are 3 checks you can safely do yourself first.
- Switch the appliance off at the socket for a minute, then back on — occasionally the alarm was a one-off reading and clears.
- If the ice maker is switched off in the menu, turn it back on and see whether the code returns.
- Check the ice bin and dispenser chute are not blocked with a solid lump of ice, and clear anything obvious by hand.
This one usually needs an engineer once you have tried them.
How much does it cost to repair Blomberg E08?
£66 including VAT for an engineer to come out and diagnose it, or £84 in total including VAT if it is put right on the visit and no parts are needed. Any parts needed are quoted on site before we fit them — you decide. Every repair carries a 90-day workmanship guarantee.
Tried the checks and it's still showing E08?
This one usually needs an engineer once you have tried the checks above. Then it wants someone who can open it up.
What it costs, before you call: the price is the same whatever the fault turns out to be — £66 including VAT for an engineer to come out and diagnose it, or £84 in total including VAT if it is put right on the visit and no parts are needed. Any parts needed are quoted on site before we fit them — you decide. Every repair carries a 90-day workmanship guarantee.
Our own engineers, not a call centre. We cover Nottinghamshire, Derbyshire and Leicestershire — most fridge freezer faults are seen same day or next day.
Call 0115 648 0929 Book online — postcode and number is all we need
Outside our area? The explanation above still stands — take it to a local engineer and tell them the code. Knowing it saves them time and you money.
Other Blomberg fridge freezer codes
- Blomberg E09 — The automatic ice maker isn't turning as it should, so the f…
- Blomberg E10 — The temperature sensor for the convertible "joker" compartme…
- Blomberg E11 — The temperature sensor on the evaporator (the cooling coil) …
- Blomberg E12 — The heater that melts frost off the cooling plate in the con…
- Blomberg E13 — The control board has decided the motorised flap that lets c…
- Blomberg E14 — One of the fridge freezer's internal cooling fans has stoppe…
- Blomberg E15 — The control board has lost the expected signal from the cond…
- Blomberg E16 — The fan that circulates cold air around the fridge section i…
All Blomberg fault codes and repairs →