What C05 actually means
The hob has spotted that one of its main power relays isn't releasing properly, so it has shut the cooking zones down rather than risk leaving power switched on.
Inside the hob, relays on the power board switch mains power through to the induction coils. The control electronics monitor those contacts, and when they detect a relay staying closed when it should have opened \u2014 sticking contacts \u2014 the hob locks out and shows this code. Electrolux's own service information for these hobs points straight at the power board itself, not at anything the cooking surface or controls are doing.
What C05 looks like on a Electrolux hob
Most people find this page having searched for what the machine is doing rather than the code itself. On a Electrolux hob, C05 usually shows up as one or more of these:
- Not heating up
- Takes ages to get to temperature
- Cuts out part way through cooking
- Noisy fan
- Not getting cold evenly
- Cuts out after a few minutes
- No function at all
- Dead — nothing lights up
Recognise any of those? That is this fault, and the rest of this page explains what causes it and what you can check yourself.
What usually causes it
- Welded or sticking main relay contacts on the power board
- A failed power board after years of switching heavy induction loads
- Heat stress inside the hob's electronics housing
- Occasionally a one-off glitch that clears after the hob is isolated from the mains
What you can safely check yourself
Work through these in order. Anything beyond this — panels off, testing parts, anything to do with the wiring — is an engineer's job, and not one to attempt with the machine plugged in.
- Turn the hob off at the wall switch or trip its breaker, leave it for a minute, then power it back up \u2014 if the code returns straight away or comes back within a cooking session, it is a genuine board fault
- Check nothing is blocking the ventilation gap around or beneath the hob, such as items stored tight against it in the cupboard below
Which Electrolux models show C05
C05 means the same thing on all 2 of these models. If yours is not listed, the explanation above still applies — the code is set by the control board, not the model number.
47635IP-MN · 47645IQ-WN
Common questions about Electrolux C05
What does C05 mean on a Electrolux hob?
The hob has spotted that one of its main power relays isn't releasing properly, so it has shut the cooking zones down rather than risk leaving power switched on. Inside the hob, relays on the power board switch mains power through to the induction coils. The control electronics monitor those contacts, and when they detect a relay staying closed when it should have opened \u2014 sticking contacts \u2014 the hob locks out and shows this code. Electrolux's own service information for these hobs points straight at the power board itself, not at anything the cooking surface or controls are doing.
Can I fix Electrolux C05 myself?
There are 2 checks you can safely do yourself first.
- Turn the hob off at the wall switch or trip its breaker, leave it for a minute, then power it back up \u2014 if the code returns straight away or comes back within a cooking session, it is a genuine board fault.
- Check nothing is blocking the ventilation gap around or beneath the hob, such as items stored tight against it in the cupboard below.
This one usually needs an engineer once you have tried them.
How much does it cost to repair Electrolux C05?
£66 including VAT for an engineer to come out and diagnose it, or £84 in total including VAT if it is put right on the visit and no parts are needed. Any parts needed are quoted on site before we fit them — you decide. Every repair carries a 90-day workmanship guarantee.
Tried the checks and it's still showing C05?
This one usually needs an engineer once you have tried the checks above. Then it wants someone who can open it up.
What it costs, before you call: the price is the same whatever the fault turns out to be — £66 including VAT for an engineer to come out and diagnose it, or £84 in total including VAT if it is put right on the visit and no parts are needed. Any parts needed are quoted on site before we fit them — you decide. Every repair carries a 90-day workmanship guarantee.
Our own engineers, not a call centre. We cover Nottinghamshire, Derbyshire and Leicestershire — most hob faults are seen same day or next day.
Call 0115 648 0929 Book online — postcode and number is all we need
Outside our area? The explanation above still stands — take it to a local engineer and tell them the code. Knowing it saves them time and you money.
Other Electrolux hob codes
- Electrolux C06 — The hob has spotted a problem with the cooling fan that keep…
- Electrolux C07 — The hob has measured a mains supply voltage outside the rang…
- Electrolux C08 — The hob's power board has measured the electrical current co…
- Electrolux E00 — The hob's two circuit boards aren't talking to each other pr…
- Electrolux E01 — The hob's power electronics and its touch control are not se…
- Electrolux E02 — The hob has shut a zone down because the electronics underne…
- Electrolux E03 — The hob has measured the incoming mains voltage as too high …
- Electrolux E04 — The hob has lost the temperature sensor reading on one of it…
All Electrolux fault codes and repairs →